Solenoid Valve, Liquid Line Solenoid & Defrost Solenoid Valve Selection

Solenoid valve is an on-off control component; cuts off or opens refrigerant flow according to electric signal from controller. Liquid line solenoid valve: before expansion valve; closes automatically when thermostat reaches set temperature, stops liquid supply. Without liquid solenoid valve, refrigerant will continue migrating to evaporator during compressor off period, causing flood-back at next startup. Hot gas defrost solenoid valve: controls high pressure hot gas entering air cooler coil for defrost cycle. Solenoid coil has different voltage options: 24VAC, 220VAC, 380VAC, must match local export power standard. Xiteliduo rack system uses pilot operated solenoid valve for large flow, direct acting type for small capacity circuit. Direct acting: small flow, low pressure difference; pilot operated: big flow, suitable for large refrigeration circuit. Solenoid valve must be installed with flow arrow direction; debris stuck on valve seat causes internal leakage. Valve seat leakage symptom: compressor still pumps down slowly after shutdown, continuous frost on valve outlet side. Refrigeration maintenance & repair judge solenoid leakage when cooling keeps running after room temperature reaches target.

FAQ

  1. What is the function of liquid line solenoid valve? Cut liquid supply when thermostat satisfies set temperature.
  2. What risk without liquid solenoid valve? Refrigerant migration and liquid flood-back on startup.
  3. What solenoid controls hot gas defrost? Defrost hot gas solenoid valve.
  4. What is the difference between direct acting and pilot solenoid? Direct acting for small flow; pilot operated for large flow.
  5. What is the common fault of solenoid valve? Foreign matter stuck on seat causing internal leakage.
  6. What symptom of solenoid seat leakage? Outlet side keeps frosting after closing signal.
  7. What voltage options for export solenoid coil? 24VAC, 220VAC, 380VAC.
  8. Does solenoid valve need to follow flow arrow? Yes.
इस लेख का वेबसाइट: https://hi.xtldcool.com/news/848.html

ऑनलाइन उत्पाद अनुकूलन योजनाएँ प्राप्त करें

कृपया नीचे दिए गए बॉक्स में आवश्यक जानकारी भरें, और आप इसे मुफ्त में प्राप्त कर सकेंगे।

परामर्श हेल्पलाइन

+86-18157593311

साइटेलिडुओ और चुआनली

R32 सेमी-हर्метиक पिस्टन कम्प्रेसर और कस्टम टर्नकी औद्योगिक रेफ्रिजरेशन सिस्टम के लिए चाइना सोर्स फैक्ट्री। स्व-विकसित कम्प्रेसर + पूर्ण रेफ्रिजरेशन समाधान, उष्णकटिबंधीय और अति-निम्न तापमान वाली कार्य स्थितियों के लिए स्थिर प्रदर्शन।

हमसे जुड़ें

तकनीकी सेवाएँ: +86-575-83665888;83068555 
कंप्रेसर हॉटलाइन: +86-18157593311 
इलेक्ट्रिक हीटिंग ट्यूब हॉटलाइन: +86-13857577938 
ईमेल:helenliu1983xtld@gmail.com
इलेक्ट्रिक हीटिंग ट्यूब फैक्ट्री: नंबर 150, डोंगहु गाँव, गानलिन टाउन, शेंगझोउ शहर, शाओक्सिंग शहर 
कंप्रेसर फैक्ट्री: नंबर 679, डोंगगुआ आर्थिक विकास क्षेत्र, शेंगझोउ शहर, शाओक्सिंग शहर

कॉपीराइट © 2026 झेजियांग ज़िटेलिडु एनवायरनमेंटल टेक्नोलॉजी कं., लिमिटेड और शेंगचुआनली एनवायरनमेंटल टेक्नोलॉजी कं., लिमिटेड। सर्वाधिकार सुरक्षित।