Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

  • उनका वर्गीकरण:
  • दृश्य: ...
  • रिलीज का समय: 2026-10-31

Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

Shell and tube water cooled condenser: high pressure refrigerant gas outside tubes, cooling water flows inside copper tubes for heat exchange. Heat transfer efficiency is higher than air cooled type, stable condensing temperature, suitable for large rack unit and high heat load. Cooling water takes heat away and flows to cooling tower for re-cooling; water system needs water pump, pipeline, water treatment. Water quality control is critical: high hardness water causes scale attached on inner tube wall, heat transfer capacity drops sharply. Xiteliduo shell and tube condenser adopts seamless copper tube, can be matched with open type or closed cooling tower. Water flow rate must keep within design range; insufficient water flow leads to high condensing pressure; excessive flow wastes pump power. Water side chemical cleaning is required periodically; scale, slime and algae are hard to remove once thickened. Winter low ambient region needs water circuit anti-freeze: drain water, add antifreeze or install tracing heating cable. Water cooled system has more auxiliary equipment, higher initial investment and maintenance cost than air cooled solution. Refrigeration maintenance & repair company monitors water inlet/outlet temperature difference to judge fouling degree.

FAQ

  1. What is the mainstream structure of water cooled condenser? Shell and tube type.
  2. Which medium flows inside the tube? Cooling water.
  3. What is the advantage of water cooled condenser? Higher heat exchange efficiency, stable condensing pressure.
  4. What is the main hazard of hard cooling water? Scale formation on inner tube wall.
  5. What equipment is needed to cooperate with water cooled condenser? Cooling tower and water circulation pump.
  6. How to judge water side fouling? Water temperature difference becomes smaller than design value.
  7. What protection for water circuit in cold winter? Drain water, antifreeze liquid or heat tracing.
  8. What is the disadvantage of water cooled system? Extra water system investment and maintenance work.
इस लेख का वेबसाइट: https://hi.xtldcool.com/news/843.html

ऑनलाइन उत्पाद अनुकूलन योजनाएँ प्राप्त करें

कृपया नीचे दिए गए बॉक्स में आवश्यक जानकारी भरें, और आप इसे मुफ्त में प्राप्त कर सकेंगे।

परामर्श हेल्पलाइन

+86-18157593311

साइटेलिडुओ और चुआनली

R32 सेमी-हर्метиक पिस्टन कम्प्रेसर और कस्टम टर्नकी औद्योगिक रेफ्रिजरेशन सिस्टम के लिए चाइना सोर्स फैक्ट्री। स्व-विकसित कम्प्रेसर + पूर्ण रेफ्रिजरेशन समाधान, उष्णकटिबंधीय और अति-निम्न तापमान वाली कार्य स्थितियों के लिए स्थिर प्रदर्शन।

हमसे जुड़ें

तकनीकी सेवाएँ: +86-575-83665888;83068555 
कंप्रेसर हॉटलाइन: +86-18157593311 
इलेक्ट्रिक हीटिंग ट्यूब हॉटलाइन: +86-13857577938 
ईमेल:helenliu1983xtld@gmail.com
इलेक्ट्रिक हीटिंग ट्यूब फैक्ट्री: नंबर 150, डोंगहु गाँव, गानलिन टाउन, शेंगझोउ शहर, शाओक्सिंग शहर 
कंप्रेसर फैक्ट्री: नंबर 679, डोंगगुआ आर्थिक विकास क्षेत्र, शेंगझोउ शहर, शाओक्सिंग शहर

कॉपीराइट © 2026 झेजियांग ज़िटेलिडु एनवायरनमेंटल टेक्नोलॉजी कं., लिमिटेड और शेंगचुआनली एनवायरनमेंटल टेक्नोलॉजी कं., लिमिटेड। सर्वाधिकार सुरक्षित।