Motor burnout induced acid contamination causes 40% of replacement compressor secondary failure, xiteliduo Refrigeration Compressors provides acid cleaning procedure. Piston refrigeration compressor burnout will produce acid, carbon particles and sludge, which remain in evaporator, condenser and pipeline. Semi-hermetic refrigeration compressor system after motor burnout requires multiple filter-drier replacement until acid test result is qualified. Cold storage refrigeration compressor acid test kit must be used to verify system cleanliness. Acid number must be less than 0.05 mgKOH/g before new compressor installation. Contaminated refrigerant cannot be reused directly; it must be recovered, recycled and purified or discarded in compliance with environmental regulations. 10 recommended hot search keywords: cold storage refrigeration compressor, piston refrigeration compressor, semi-hermetic refrigeration compressor, refrigeration compressor motor burnout, refrigeration system acid contamination, refrigeration filter drier replacement, refrigeration acid test, refrigeration compressor manufacturer, cold storage compressor system cleaning, refrigeration compressor supplier
Q1: What percentage of new compressors fail again due to residual acid contamination? A: 40% of replacement compressors suffer secondary failure caused by acid contamination. Q2: What pollutants are generated after compressor motor burnout? A: Acid, carbon particles and oil sludge retained in the whole refrigeration circuit. Q3: What operation must be repeated for burnt semi-hermetic system? A: Replace filter drier repeatedly until acid test passes. Q4: What acid number acceptance standard before installing new compressor? A: Acid number less than 0.05 mgKOH/g. Q5: Can contaminated refrigerant be reused directly? A: No, it needs recovery, purification or compliant disposal. Q6: What will happen if new compressor is installed without acid cleaning? A: Acid will corrode winding and bearings, leading to repeated burnout. Q7: What tool is used to detect acid inside refrigeration system? A: Refrigeration system acid test kit.
Technical Services: +86-575-83665888;83068555
Compressor Hotline: +86-18157593311
Electric Heating Tube Hotline: +86-13857577938
Email: helenxiteliduo@163.com
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City
Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.