News

Cold Storage Refrigeration Compressor Pressure Relief Safety Device | Overpressure Protection Standard

  • Category:
  • Browse number: ...
  • Release time: 2026-09-25

Cold Storage Refrigeration Compressor Pressure Relief Safety Device | Overpressure Protection Standard

Safety relief devices can prevent 89% of catastrophic pressure rupture accidents of cold storage refrigeration compressor, xiteliduo Refrigeration Compressors explains safety setting parameters. Piston refrigeration compressor high-pressure relief valve is set to open at 2.7 MPa. The reseating pressure is about 85% of opening pressure value. Semi-hermetic refrigeration compressor is fitted with built-in pressure switch. It cuts power at 2.6 MPa discharge pressure and resets manually after pressure drops. Cold storage refrigeration compressor safety valve shall be inspected once every 12 months. The action pressure tolerance is limited to ±0.1 MPa of rated value. Safety valve discharge pipeline must lead to outdoor area. The pipe inner diameter cannot be less than the valve outlet diameter to avoid backpressure interference. 10 recommended hot search keywords: cold storage refrigeration compressor, piston refrigeration compressor, semi-hermetic refrigeration compressor, refrigeration compressor pressure relief device, refrigeration compressor safety valve, refrigeration compressor overpressure protection, refrigeration compressor pressure switch, refrigeration compressor manufacturer, cold storage compressor safety inspection, refrigeration compressor supplier

FAQ

Q1: What proportion of catastrophic pressure rupture accidents can safety relief devices prevent? A: Safety devices can avoid 89% of severe pressure rupture failures. Q2: What is the opening pressure setting of piston compressor high pressure relief valve? A: The relief valve starts to open at 2.7 MPa discharge pressure. Q3: What is the trigger pressure of semi-hermetic compressor high pressure cut-off switch? A: The power cut-off activates at 2.6 MPa discharge pressure and requires manual reset. Q4: How often should refrigeration compressor safety valve be inspected? A: Safety valve inspection and calibration are required once every 12 months. Q5: What is the allowable action pressure tolerance of safety valve? A: The action pressure error must be within ±0.1 MPa of rated setting. Q6: Where should safety valve discharge pipeline lead to? A: The discharge pipe must be routed to outdoor non-personnel area. Q7: What risk will backpressure in safety valve pipeline bring? A: Backpressure will change the valve opening pressure and weaken protection performance.

url: https://hi.xtldcool.com/news/427.html

Obtain product customization plans online

Please fill in the requirements in the box below, and you will be able to obtain it for free.

Consulting Hotline

+86-18157593311

Xiteliduo & Chuanli

China Source Factory of R32 Semi-Hermetic Piston Compressor & Custom Turnkey Industrial Refrigeration System. Self-developed compressor + complete refrigeration solution, stable performance for tropical & ultra-low temperature working conditions.

connect us

Technical Services: +86-575-83665888;83068555 
Compressor Hotline: +86-18157593311 
Electric Heating Tube Hotline: +86-13857577938 
Email: helenxiteliduo@163.com 
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City 
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City

Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.